# Terminal (multi-pin) wave ports in Palace

A wave port reports *modal* S-parameters. A circuit needs *terminal* S-parameters: one port per conductor, with a reference impedance you choose. This notebook builds the terminal S-parameters of a coupled GSSG line on the generic PDK, following the guide [Terminal (multi-pin) Wave Ports](<https://gdsfactory.com/gsim/terminal_wave_ports/index.md>):

1. a 2D `BoundaryModeSim` on the port plane gives the terminal voltages and currents of every mode (`T_V`, `T_I`), with the conductors as perfect conductors like the port eigenproblem of the 3D run;
2. a 3D `DrivenSim` with one **multimode wave port** per end gives the modal S-parameters;
3. `terminal_s` pairs the 2D and 3D modes, puts `T_V` and `T_I` into the gauge of Palace's port modes and converts.

The notebook has two parts. Everything up to the cloud sections runs locally: geometry, terminal layout and voltage paths, 2D and 3D meshing, the generated Palace configuration and the job sizes. The cloud sections are present but guarded by `RUN_CLOUD = False`; they need a [GDSFactory+](<https://gdsfactory.com>) account and are run by hand.

Two lines are used, both on `metal3` of the generic PDK (S width 10 um, gap 6 um, edge-to-edge S-S spacing 20 um, G width 40 um, length 300 um, 1 to 50 GHz):

- **`float`**: GSSG with floating outer grounds. Terminals G1, S1, S2, reference G2: three terminals, three modes.
- **`tied`**: the outer grounds tied by a `metal1` plane and continuous via walls. Terminals S1, S2, reference the plane: two terminals, two modes.

```python
import json
import tempfile
from pathlib import Path

import gdsfactory as gf
import matplotlib.pyplot as plt
import numpy as np

import gsim
from gsim.common.cross_section import extract_plane_section
from gsim.common.modes import Conductor
from gsim.common.stack import get_stack
from gsim.palace import (
    BoundaryModeSim,
    DrivenSim,
    TerminalPortSpec,
    declare_terminal_paths,
    plot_plane_section,
    terminal_paths,
)
from gsim.palace.ports.modes import read_port_modes

gf.gpdk.PDK.activate()
LAYER = gf.gpdk.LAYER

# Submit the cloud jobs of sections 5 to 7 when True. Off: the notebook is a local dry run.
RUN_CLOUD = False
# The line to work on: "float" (three terminals) or "tied" (two terminals).
KIND = "float"

WORK = Path(tempfile.mkdtemp(prefix="palace-terminal-"))
```

## 1\. Geometry

The four strips sit on `metal3`. The `tied` line adds a `metal1` plane under the whole width and a 4 um wide wall of `via2`, `metal2` and `via1` under each outer ground, so the two grounds and the plane are one conductor. The ports sit at the signal centre (between the two signals); with `max_size=True` the port face is the whole simulation domain, so it holds every conductor.

```python
LENGTH = 300.0  # um
S_W, GAP, SS, G_W = (
    10.0,
    6.0,
    20.0,
    40.0,
)  # signal width, gap, edge-to-edge S-S spacing, ground width
WALL_W = 4.0  # width of the via walls under the outer grounds
FMIN, FMAX, NUM_POINTS = 1e9, 50e9, 50
# The 2D solves (section 3): gauge solves with PEC conductors, at the frequencies where 3D run 1 saves Palace's
# own port-mode fields, and lossy solves for the propagation constant gamma of the line.
FREQS_GAUGE = (1e9, 10e9, 50e9)
FREQS_LOSSY = (1e9, 5e9, 20e9, 50e9)
assert all(
    np.isclose(np.linspace(FMIN, FMAX, NUM_POINTS), f).any() for f in FREQS_GAUGE
)

S_IN = SS / 2
STRIPS = {  # (y0, y1) of every strip
    "G1": (-(S_IN + S_W + GAP + G_W), -(S_IN + S_W + GAP)),
    "S1": (-(S_IN + S_W), -S_IN),
    "S2": (S_IN, S_IN + S_W),
    "G2": (S_IN + S_W + GAP, S_IN + S_W + GAP + G_W),
}
Y_EDGE = STRIPS["G2"][1]

stack = get_stack()
Z = {
    name: (stack.layers[name].zmin, stack.layers[name].zmax)
    for name in ("metal1", "metal3")
}
MARGIN_Y, Z_ABOVE, Z_BELOW = 60.0, 60.0, 20.0  # airbox margins (um)
Z_OXIDE = (-2.0, 5.2)  # the oxide slab of set_stack(substrate_thickness=2.0)
# the meshed domain of every run below: the port face and the 2D cross-section
DOMAIN = (
    (-(Y_EDGE + MARGIN_Y), Y_EDGE + MARGIN_Y),
    (Z_OXIDE[0] - Z_BELOW, Z_OXIDE[1] + Z_ABOVE),
)


def _rect(c, y0, y1, layer):
    c.add_polygon(
        [(-LENGTH / 2, y0), (LENGTH / 2, y0), (LENGTH / 2, y1), (-LENGTH / 2, y1)],
        layer=layer,
    )


def build_component(kind):
    # The "float" or "tied" line with ports o1 (x < 0) and o2 (x > 0).
    c = gf.Component()
    for y0, y1 in STRIPS.values():
        _rect(c, y0, y1, LAYER.M3)
    if kind == "tied":
        _rect(c, -Y_EDGE, Y_EDGE, LAYER.M1)
        for name in ("G1", "G2"):
            y_mid = sum(STRIPS[name]) / 2
            for layer in (LAYER.VIA1, LAYER.M2, LAYER.VIA2):
                _rect(c, y_mid - WALL_W / 2, y_mid + WALL_W / 2, layer)
    for name, x, angle in (("o1", -LENGTH / 2, 180), ("o2", LENGTH / 2, 0)):
        c.add_port(
            name=name,
            center=(x, 0),
            width=S_W,
            orientation=angle,
            port_type="electrical",
            layer=LAYER.M3,
        )
    return c


def make_spec(kind, name="P"):
    # The terminals and the reference as rectangles (h = y, v = z, um) of the x = const cross-section.
    z3 = Z["metal3"]
    if kind == "float":
        terminals = [Conductor(n, (STRIPS[n], z3)) for n in ("G1", "S1", "S2")]
        reference = Conductor("G2", (STRIPS["G2"], z3))
    else:
        terminals = [Conductor(n, (STRIPS[n], z3)) for n in ("S1", "S2")]
        reference = Conductor("PLANE", ((-Y_EDGE, Y_EDGE), Z["metal1"]))
    return TerminalPortSpec(name=name, terminals=terminals, reference=reference)


NUM_MODES = {"float": 3, "tied": 2}
print(
    {k: len(make_spec(k).terminals) for k in NUM_MODES}, "terminals;", "domain", DOMAIN
)
```

```text
{'float': 3, 'tied': 2} terminals; domain ((-126.0, 126.0), (-22.0, 65.2))
```

## 2\. Terminal layout and voltage paths

`terminal_paths` draws one voltage path per terminal, from the terminal to the reference conductor. A path never crosses a conductor: it goes straight across the gap when the terminal and the reference face each other, otherwise out of the terminal at mid-height, over the metal and down onto the reference. The same paths are declared on the 2D solve (Palace then writes the voltage of every mode on every path to `mode-V.csv`) and, for one *pilot* terminal per mode, on the 3D port as its `VoltagePath`.

```python
fig, axes = plt.subplots(2, 1, figsize=(10, 7))
for ax, kind in zip(axes, ("float", "tied"), strict=True):
    section = extract_plane_section(
        build_component(kind).copy(), stack, axis="x", value=0.0
    )
    plot_plane_section(
        section,
        h_range=(-80, 80),
        v_range=(0, 12),
        title=f"{kind}: x = 0",
        ax=ax,
        legend=False,
    )
    for name, points in terminal_paths(make_spec(kind), DOMAIN).items():
        h, v = zip(*points, strict=True)
        ax.plot(h, v, "-o", ms=2.5, lw=1.2, label=f"path to the reference: {name}")
    ax.legend(loc="upper right", fontsize=7)
plt.tight_layout()
plt.show()
```

![svg](<https://gdsfactory.com/gsim/nbs/palace_terminal_waveport_files/palace_terminal_waveport_5_0.svg>)

## 3\. The 2D solves (local meshing)

One `BoundaryModeSim` per frequency on the plane `x = 0`, with `metallic_boundaries=True` because the 3D port solve treats the outer wall as PEC. The port solve also treats the finite-conductivity *conductor surfaces* as PEC, whereas a 2D solve keeps them as Robin conductivity conditions unless `conductor_boundary="pec"` is set: its modes are then lossy, with a complex, frequency-dependent `n_eff` (about 12 % away from the port solve's at 1 GHz on this line), and cannot be paired with the port modes within 0.5 %. There are therefore two kinds of 2D solve:

- **gauge solves** (`conductors="pec"`): the modes of the port eigenproblem. They give `T_V`, `T_I` and the `n_eff` that `align_gauge` pairs with the 3D port modes. With PEC conductors they hardly move with frequency, so a few solves are enough; they are at the frequencies where 3D run 1 saves Palace's own port-mode fields (`FREQS_GAUGE`).
- **lossy solves** (`conductors="conductivity"`, the default of `BoundaryModeSim`): the physical line. Only their propagation constant `gamma = j k0 n_eff` is used, as the reference of the uniform-line check (`FREQS_LOSSY`).

The shielded domain has the outer wall as one more conductor, so one mode more than terminals is asked for and saved; the extra mode is the wall mode, expected last by effective index (check `mode-kn.csv` after the run). The mode solve itself needs Palace and runs in the cloud (section 5).

```python
MESH_2D = {
    "preset": "default",
    "refined_mesh_size": 1.0,
    "max_mesh_size": 20.0,
    "fmax": FMAX,
}


def build_2d(kind, freq_hz, out, *, conductors="pec", target=0.0):
    # A configured, meshed BoundaryModeSim on x = 0 with the terminal paths declared.
    # conductors="pec": a gauge solve (the conductor surfaces are perfect conductors, as in the 3D port
    # eigenproblem); "conductivity": the lossy line, solved for its propagation constant only.
    gauge = conductors == "pec"
    sim = BoundaryModeSim()
    sim.set_output_dir(str(out))
    sim.set_geometry(build_component(kind))
    sim.set_stack(substrate_thickness=2.0)
    sim.set_airbox(margin_x=0.0, margin_y=MARGIN_Y, z_above=Z_ABOVE, z_below=Z_BELOW)
    sim.set_cross_section("x=0")
    sim.set_boundary_mode(
        freq=freq_hz,
        num_modes=NUM_MODES[kind] + 1,
        save=NUM_MODES[kind] + 1 if gauge else 0,
        target=target,
    )
    sim.metallic_boundaries = True
    sim.conductor_boundary = conductors
    sim.mesh(verbose=False, **MESH_2D)
    # Palace controls its path integration; mode-V.csv is a separate cross-check.
    indices = declare_terminal_paths(sim, make_spec(kind), sim.mesh_extent)
    return sim, indices


sim_2d, path_indices = build_2d(KIND, 20e9, WORK / "2d")
domain = sim_2d.mesh_extent
assert np.allclose(np.array(domain), np.array(DOMAIN)), (domain, DOMAIN)
print("2D domain (h, v):", domain)
print("palace path indices:", path_indices, [p.name for p in sim_2d.mode_paths])
print("validate_config:", sim_2d.validate_config().valid)

# What conductors="pec" changes: the conductor attributes move from Conductivity to PEC, nothing else.
sim_lossy, _ = build_2d(KIND, 20e9, WORK / "2d_lossy", conductors="conductivity")
boundaries = {
    name: json.loads(Path(s.write_config()).read_text())["Boundaries"]
    for name, s in (("gauge", sim_2d), ("lossy", sim_lossy))
}
robin = sorted(a for e in boundaries["lossy"]["Conductivity"] for a in e["Attributes"])
print(
    "lossy solve: Conductivity attributes",
    robin,
    "| PEC",
    boundaries["lossy"]["PEC"]["Attributes"],
)
print(
    "gauge solve: has Conductivity:",
    "Conductivity" in boundaries["gauge"],
    "| PEC",
    boundaries["gauge"]["PEC"]["Attributes"],
)
assert "Conductivity" not in boundaries["gauge"]
assert set(boundaries["gauge"]["PEC"]["Attributes"]) == set(robin) | set(
    boundaries["lossy"]["PEC"]["Attributes"]
)
```

```text
The stack's substrate layer 'substrate' (10 um, z=-13 to -3) is not part of the domain because include_substrate=False, so its thickness does not move the domain bottom. The bottom is z=-2 um (stack bottom) minus set_airbox(z_below=20). Use set_stack(include_substrate=True) to mesh the substrate, or set substrate_thickness / z_below to move the bottom.


The stack's substrate layer 'substrate' (10 um, z=-13 to -3) is not part of the domain because include_substrate=False, so its thickness does not move the domain bottom. The bottom is z=-2 um (stack bottom) minus set_airbox(z_below=20). Use set_stack(include_substrate=True) to mesh the substrate, or set substrate_thickness / z_below to move the bottom.


2D domain (h, v): ((-126.0, 126.0), (-22.0, 65.2))
palace path indices: [1, 2, 3] ['P:G1', 'P:S1', 'P:S2']
validate_config: True


lossy solve: Conductivity attributes [3] | PEC [5]
gauge solve: has Conductivity: False | PEC [3, 5]
```

## 4\. The 3D runs (local meshing and configuration)

`add_multimode_wave_port` keeps one boundary surface per end and writes one Palace `WavePort` entry per mode on it. Palace terminates a face for one mode only (the *active* mode, which must have the lowest index of its face); the other modes are observed (`"Active": false`). Two ways to get the modal S-parameters:

- **single run**: mode 1 active and every entry excited. One run, but the modes other than the active one see a mismatched face, so their columns are approximate.
- **cycling**: one run per mode, with that mode active and only the active entries excited. The column of mode `k` comes from run `k` (exact for a mode without conversion). Run 1 is the single run, whose mode-1 columns are exact.

Each entry may carry a pilot `VoltagePath`: Palace flips the mode so that the voltage along it is positive, which fixes the sign of the mode. The pilot terminal of every mode must be the one `terminal_s` uses to fix the phase of the 2D mode. It is known only after the 2D solve (the terminal with the largest voltage in the mode), so a placeholder is used here (`S1` for every mode) and section 5 replaces it. Run 1 also saves Palace's own port-mode fields at the gauge frequencies (`save_fields_at`); `terminal_s` fits the 2D modes to them (section 7).

```python
MESH_3D = {
    "preset": "default",
    "refined_mesh_size": 2.0,
    "max_mesh_size": 40.0,
    "fmax": FMAX,
}
PORT_X = {"o1": -LENGTH / 2, "o2": LENGTH / 2}
# run name -> (active mode, which entries are excited)
RUNS = {
    "float": {"run1": (1, "all"), "run2": (2, "active"), "run3": (3, "active")},
    "tied": {"run1": (1, "all"), "run2": (2, "active")},
}


def pilot_paths_3d(kind, port, pilot):
    # {mode: [(x, y, z), ...]}: the 2D voltage path of the pilot terminal of each mode, on the port plane.
    paths = terminal_paths(make_spec(kind, port), DOMAIN)
    return {
        mode: [[PORT_X[port], h, v] for h, v in paths[name]]
        for mode, name in pilot.items()
    }


def build_3d(kind, run, pilot, out, *, save_fields_at=None):
    # A configured, meshed DrivenSim of one run of the cycle.
    active, excite = RUNS[kind][run]
    modes = tuple(range(1, NUM_MODES[kind] + 1))
    sim = DrivenSim()
    sim.set_output_dir(str(out))
    sim.set_geometry(build_component(kind))
    sim.set_stack(substrate_thickness=2.0)
    sim.set_airbox(margin_x=0.0, margin_y=MARGIN_Y, z_above=Z_ABOVE, z_below=Z_BELOW)
    for port in ("o1", "o2"):
        sim.add_multimode_wave_port(
            port,
            layer="metal3",
            modes=modes,
            active_mode=active,
            excite=excite,
            max_size=True,
            pilot_paths=pilot_paths_3d(kind, port, pilot),
        )
    # adaptive sampling off: a full solve at every point, and a port-mode solve to read the wave numbers from
    sim.set_driven(
        fmin=FMIN,
        fmax=FMAX,
        num_points=NUM_POINTS,
        adaptive_tol=0.0,
        save_fields_at=save_fields_at,
    )
    mesh = sim.mesh(verbose=False, **MESH_3D)
    return sim, mesh.mesh_stats["tetrahedra"]


PILOT = dict.fromkeys(
    range(1, NUM_MODES[KIND] + 1), "S1"
)  # placeholder until the 2D solve
jobs_table = []
for run in RUNS[KIND]:
    sim, tetrahedra = build_3d(
        KIND,
        run,
        PILOT,
        WORK / run,
        save_fields_at=list(FREQS_GAUGE) if run == "run1" else None,
    )
    assert sim.validate_config().valid
    config = json.loads(Path(sim.write_config()).read_text())
    entries = config["Boundaries"]["WavePort"]
    jobs_table.append(
        (run, tetrahedra, len(entries), sum(bool(e.get("Excitation")) for e in entries))
    )
```

```text
The stack's substrate layer 'substrate' (10 um, z=-13 to -3) is not part of the domain because include_substrate=False, so its thickness does not move the domain bottom. The bottom is z=-2 um (stack bottom) minus set_airbox(z_below=20). Use set_stack(include_substrate=True) to mesh the substrate, or set substrate_thickness / z_below to move the bottom.


The stack's substrate layer 'substrate' (10 um, z=-13 to -3) is not part of the domain because include_substrate=False, so its thickness does not move the domain bottom. The bottom is z=-2 um (stack bottom) minus set_airbox(z_below=20). Use set_stack(include_substrate=True) to mesh the substrate, or set substrate_thickness / z_below to move the bottom.


Info    : Reading 'palace.msh'...
Info    : 15701 nodes
Info    : 106592 elements
Info    : [  0%] Reading elements
```

Info : \[ 10%\] Reading elements  
Info : \[ 20%\] Reading elements  
Info : \[ 30%\] Reading elements  
Info : \[ 40%\] Reading elements  
Info : \[ 50%\] Reading elements  
Info : \[ 60%\] Reading elements  
Info : \[ 70%\] Reading elements  
Info : \[ 80%\] Reading elements  
Info : \[ 90%\] Reading elements

Info : Done reading 'palace.msh'

```text
Info    : Reading 'palace.msh'...
Info    : 15701 nodes
Info    : 106592 elements
Info    : [  0%] Reading elements
```

Info : \[ 10%\] Reading elements  
Info : \[ 20%\] Reading elements  
Info : \[ 30%\] Reading elements  
Info : \[ 40%\] Reading elements  
Info : \[ 50%\] Reading elements  
Info : \[ 60%\] Reading elements  
Info : \[ 70%\] Reading elements  
Info : \[ 80%\] Reading elements  
Info : \[ 90%\] Reading elements

Info : Done reading 'palace.msh'

```text
The stack's substrate layer 'substrate' (10 um, z=-13 to -3) is not part of the domain because include_substrate=False, so its thickness does not move the domain bottom. The bottom is z=-2 um (stack bottom) minus set_airbox(z_below=20). Use set_stack(include_substrate=True) to mesh the substrate, or set substrate_thickness / z_below to move the bottom.


Info    : Reading 'palace.msh'...
Info    : 15701 nodes
Info    : 106592 elements
Info    : [  0%] Reading elements
```

Info : \[ 10%\] Reading elements  
Info : \[ 20%\] Reading elements  
Info : \[ 30%\] Reading elements  
Info : \[ 40%\] Reading elements  
Info : \[ 50%\] Reading elements  
Info : \[ 60%\] Reading elements  
Info : \[ 70%\] Reading elements  
Info : \[ 80%\] Reading elements  
Info : \[ 90%\] Reading elements

Info : Done reading 'palace.msh'

```python
print(f"{'run':6s} {'tetrahedra':>11s} {'WavePort entries':>17s} {'excitations':>12s}")
for run, tets, n_entries, n_exc in jobs_table:
    print(f"{run:6s} {tets!s:>11s} {n_entries:17d} {n_exc:12d}")

print("\nPalace index -> (port, mode, active, excited) of run1 (port_modes.json):")
for row in read_port_modes(WORK / "run1"):
    print(
        f"  {row.index}: {row.port} mode {row.mode}  active={row.active}  excited={row.excited}"
    )
```

```text
run     tetrahedra  WavePort entries  excitations
run1         78474                 6            6
run2         78474                 6            2
run3         78474                 6            2

Palace index -> (port, mode, active, excited) of run1 (port_modes.json):
  1: o1 mode 1  active=True  excited=True
  2: o2 mode 1  active=True  excited=True
  3: o1 mode 2  active=False  excited=True
  4: o1 mode 3  active=False  excited=True
  5: o2 mode 2  active=False  excited=True
  6: o2 mode 3  active=False  excited=True
```

## 5\. Cloud: the 2D solves

Three **gauge solves** with PEC conductors (1, 10 and 50 GHz, the frequencies where run 1 saves Palace's port-mode fields) and four **lossy solves** (1, 5, 20 and 50 GHz) for `gamma`; the 5 GHz one tests the `1/f` interpolation of `gamma` between 1 and 20 GHz. `terminal_s` interpolates `T_V` and `T_I` between the gauge solves (in `1/f`). Nothing below runs unless `RUN_CLOUD = True`. The `T_V` and `T_I` come from the saved mode fields, not from `mode-V.csv`, which is used as a cross-check of the line integrals. The gauge solves are submitted first, then the lossy ones, which wait for them because their eigenvalue `target` comes from the `n_eff` of the gauge solves.

```python
N = NUM_MODES[KIND]
spec = make_spec(KIND)
paths_2d = terminal_paths(spec, DOMAIN)

if RUN_CLOUD:
    from scipy.constants import c as C0

    from gsim.palace import (
        load_boundary_mode_field,
        port_modes_2d,
        port_terminal_matrices,
    )
    from gsim.palace.mode_fields import voltage_line_integral
    from gsim.palace.results import load_text_results

    sims_gauge = [
        build_2d(KIND, f, WORK / f"2d_pec_{f / 1e9:g}GHz")[0] for f in FREQS_GAUGE
    ]
    files_2d = gsim.wait_for_results([s.run(wait=False) for s in sims_gauge])
    # Target just above the largest PEC n_eff of the gauge solves: without it Palace's
    # automatic shift (sqrt(1.1 max eps_r)) returns spurious conductor modes below 50 GHz
    target_lossy = 1.02 * max(
        v["n_eff"].real for v in load_text_results(files_2d[0]).modes.values()
    )
    sims_lossy = [
        build_2d(
            KIND,
            f,
            WORK / f"2d_lossy_{f / 1e9:g}GHz",
            conductors="conductivity",
            target=target_lossy,
        )[0]
        for f in FREQS_LOSSY
    ]
    files_lossy = gsim.wait_for_results([s.run(wait=False) for s in sims_lossy])

    modes_2d, matrices = [], []
    for f, files in zip(FREQS_GAUGE, files_2d, strict=True):
        text = load_text_results(files)
        print(
            f"{f / 1e9:g} GHz n_eff of every saved mode (PEC conductors):",
            {m: round(v["n_eff"].real, 4) for m, v in text.modes.items()},
        )
        run_root = Path(files["mode-kn.csv"]).parent
        fields = [
            load_boundary_mode_field(run_root, mode_id=m) for m in range(1, N + 1)
        ]
        n_eff = [text.modes[m]["n_eff"].real for m in range(1, N + 1)]
        modes_2d.append(
            port_modes_2d(fields, spec, freq_ghz=f / 1e9, n_eff=n_eff, paths=paths_2d)
        )
        matrices.append(port_terminal_matrices(fields, spec, paths=paths_2d))
        # cross-check against Palace's own line integrals in mode-V.csv: same shape up to one factor per mode
        for m in range(1, N + 1):
            csv = np.array([text.mode_voltage(index=i + 1, mode=m) for i in range(N)])
            own = np.array(
                [
                    voltage_line_integral(fields[m - 1], paths_2d[n]) * 1e-6
                    for n in spec.terminal_names
                ]
            )
            ratio = csv / own
            print(
                f"   mode {m}: mode-V.csv over line integral, spread {np.ptp(np.abs(ratio)) / np.abs(ratio).mean():.2e}"
            )

    # gamma = j k0 n_eff of the lossy line (complex n_eff), the reference of the uniform-line check
    gamma_lossy = {}
    for f, files in zip(FREQS_LOSSY, files_lossy, strict=True):
        text = load_text_results(files)
        k0 = 2 * np.pi * f / C0
        gamma_lossy[f] = {m: 1j * k0 * text.modes[m]["n_eff"] for m in range(1, N + 1)}
        print(
            f"{f / 1e9:g} GHz n_eff of the lossy line:",
            {m: complex(np.round(v["n_eff"], 4)) for m, v in text.modes.items()},
        )

    # the pilot terminal of every mode: the largest voltage at the lowest frequency
    PILOT = {m + 1: spec.terminal_names[row] for m, row in enumerate(matrices[0].pilot)}
    print("pilot terminals:", PILOT)
```

## 6\. Cloud: the 3D runs

The 3D simulations are rebuilt with the real pilot paths and submitted together (at most five jobs at a time). The Palace log of each run carries the wave number of every port mode, which `terminal_s` pairs with the 2D `n_eff`.

```python
if RUN_CLOUD:
    from gsim.palace import load_modal_run, port_mode_reference_voltages

    sims_3d = {
        run: build_3d(
            KIND,
            run,
            PILOT,
            WORK / run,
            save_fields_at=list(FREQS_GAUGE) if run == "run1" else None,
        )[0]
        for run in RUNS[KIND]
    }
    ids = [s.run(wait=False) for s in sims_3d.values()]
    results_3d = gsim.wait_for_results(ids)
    runs = [
        load_modal_run(
            res.files,
            sidecar=WORK / run / "port_modes.json",
            log=res.files["palace.log"],
        )
        for run, res in zip(sims_3d, results_3d, strict=True)
    ]

    # Palace's own port-mode fields (run 1 saved them at FREQS_GAUGE; one ParaView cycle per saved frequency, in
    # ascending order) integrated along the terminal paths: the gauge reference of align_gauge, one per gauge solve.
    # Every run builds its entries with the same VoltagePath per mode, so the gauge of run 1 is the one of all runs.
    saved = sorted(FREQS_GAUGE)
    cycles = [saved.index(f) + 1 for f in FREQS_GAUGE]
    reference_voltages = {
        port: port_mode_reference_voltages(
            results_3d[0].files,
            make_spec(KIND, port),
            WORK / "run1" / "port_modes.json",
            cycles=cycles,
            domain=DOMAIN,
        )
        for port in ("o1", "o2")
    }
```

## 7\. Cloud: terminal S-parameters

`terminal_s` (or `build_terminal_s`, which keeps the pairing and the fit residuals) returns a scikit-rf network with one port per terminal (`"o1:S1"`, ...). `short_terminals` ties named terminals to the reference, and `mixed_mode` turns pairs of terminals into differential and common-mode ports. A few checks come with it: reciprocity, passivity, the pairing error of the modes and the residual of the gauge fit to Palace's saved port modes.

```python
from gsim.palace import build_terminal_s, mixed_mode, short_terminals


def analyse(net, kind):
    # Reciprocity, passivity and the differential through term of a terminal network.
    s = net.s
    report = {
        "max |S - S^T|": float(np.abs(s - s.transpose(0, 2, 1)).max()),
        "largest singular value of S": float(np.linalg.svd(s, compute_uv=False).max()),
    }
    reduced = short_terminals(net, ["o1:G1", "o2:G1"]) if kind == "float" else net
    mm = mixed_mode(reduced, [("o1:S1", "o1:S2"), ("o2:S1", "o2:S2")])
    return report, reduced, mm


if RUN_CLOUD:
    specs = [make_spec(KIND, port) for port in ("o1", "o2")]
    # the gauge is fitted to Palace's own port-mode voltages (reference_voltages), not assumed from a pilot rule
    result = build_terminal_s(
        runs,
        specs,
        {"o1": modes_2d, "o2": modes_2d},
        z_ref=50.0,
        reference_voltages=reference_voltages,
    )
    net = result.network(f"{KIND}-terminal")
    for port, aligned in result.aligned.items():
        print(
            f"{port}: n_eff pairing mismatch {aligned.mismatch:.2%}, gauge fit residual "
            f"{aligned.gauge_residual.max():.2e}, gauge scale {np.round(aligned.gauge_scale, 3).tolist()}"
        )
    report, reduced, mm = analyse(net, KIND)
    print(net)
    for key, value in report.items():
        print(f"{key}: {value:.3e}")
    net.write_touchstone(str(WORK / f"{KIND}_terminal"))

    fig, ax = plt.subplots(figsize=(8, 4))
    freq_ghz = net.f / 1e9
    for i in range(N):
        ax.plot(
            freq_ghz,
            20 * np.log10(np.abs(net.s[:, N + i, i])),
            label=f"|S({net.port_names[N + i]}, {net.port_names[i]})|",
        )
    ax.set_xlabel("f (GHz)")
    ax.set_ylabel("dB")
    ax.legend(fontsize=7)
    plt.show()
```

## What the runs should be compared with

- **Uniform-line consistency**: `modal_to_terminal_s(uniform_line_modal_s(gamma_2D, LENGTH * 1e-6), T_V, T_I)` against the terminal S above, with `gamma_2D` of the *lossy* solves (`gamma_lossy`), interpolated in `1/f` for `n_eff`, not with the port solve's lossless wave number; the `S21` phase error per mode checks the propagation constants; the gauge residual is a separate check.
- **Mixed mode**: the `tied` line's differential and common-mode ports against the PEC and PMC half models (`add_symmetry_plane`, one simulation each).
- **Grounds tied back**: `short_terminals(net, ["o1:G1", "o2:G1"])` of the `float` line against the `tied` result, below the frequency where the floating-ground mode matters. Grounds shorted at the two ends only are not continuously tied, so this is a bound. The `tied` geometry also adds a `metal1` plane under the signals, so the two lines differ in cross-section too, not only in grounding.
- **Single run against cycling**: the difference of the approximate columns of run 1 and the exact ones.